Electromagnetic Flowmeter
Specifications
Item | Technical parameter |
Main power | AC220V 50HZ/DC24V/DC12V/3.3V battery power supply |
Power consumption | <15W (Supporting power consumption with sensors ) |
Display and buttons | Display in Chinese and English, can display instantaneous flow, accumulated flow and alarm display (excitation open circuit alarm, empty pipe alarm, flow over limit alarm). Four membrane touch switches for data setting |
Counter | Forward total, reverse total |
Analog Output signal | Two-way, fully isolated 0~10mA/4~20mA Load resistance: 0~1.5kΩ when 0~10mA; 0~750Ω when 4~20mA |
Frequency output signal | Forward and reverse flow output, the upper limit of output frequency can be set within 1~5000Hz. Open collector bidirectional output of transistor with photoelectric isolation. The external power supply is not greater than 35V, and the maximum current of the collector when it is turned on is 50mA |
Alarm output signal | Two-way open collector alarm output with photoelectric isolation transistor. The external power supply is not greater than 35V, and the maximum current of the collector when it is turned on is 250mA. Alarm status: fluid empty pipe, excitation disconnection, flow overrun |
Pulse output signal | Forward and reverse flow output, the output pulse upper limit can reach 5000CP/S. Pulse equivalent is 0.0001~1.0m³/P. The pulse width is automatically set to 20ms or square wave. Open collector output of transistor with photoelectric isolation. The external power supply is not greater than 35V, and the maximum current of the collector when conducting is 50mA |
Matching accuracy | 0.5% |
Damping time constant | Continuous variable from 0~100s (90%) time grading optional |
Communication | Optional RS232C or RS485 serial communication interface, HART communication protocol |
Loss of power | The internal design of the instrument has a power-off clock, which can store 16 power-off records (10 years) (need to be customized) |
Protection class | IP65 |
Explosion-proof mark | Ex d ia [ia Ga] q IIC T6 Gb |
More Information
4800 Electromagnetic Flowmeter consisted of 4800-type flow sensor and 4800-type smart converter 4800-E Sanitary type supporting. It applies to measure (is fit for the measurement of ) the volume flow of conductive medium including the acid, alkali, salt solution, slurry, pulp, paper pulp, waste water.